18
Custom Data Transmission
The MT Series offers the option of sending one byte of custom data with
the command packet. The custom byte is entered into the transcoder
through the SIE using the Read and Write Custom Data Value commands.
This option is enabled or disabled using the Enable and Disable Custom
Data commands. The custom data byte is output on the receiving end with
the TX ID and Status bytes. Custom Data Transmission only needs to be
enabled on the transmitting side. The receiving side identifies the packet
as containing custom data and outputs the byte. This option is disabled by
default and the receiving transcoder outputs a value of 0xFF for the custom
byte.
This feature is useful for sending an 8-bit A/D value from a sensor, custom
command codes, or an additional user-defined ID for additional proprietary
system authentication. There are no restrictions on the 8-bit value, though
0xFF is not recommended for use since that is the default value with no
data.
The Custom Data is output with the Status and TX ID bytes, as described
in the Serial Output section.
Mode Entry Timings
The transcoder may enter the desired mode within minimum timings
shown in the figure below. However, if the transcoder is in another mode
at the time the CRT/LRN line goes high, then it could take longer for
the transcoder to recognize the trigger. For example, Receive Mode at
9,600bps can take 32mS to exit. For this reason, it is recommended to
increase the time to ensure that the transcoder will enter the correct mode.
Typical times are shown in the figure, but may be adjusted according to the
application.